Holkkitiivisteet - ATEX

CMP:n Atex sertifioidut holkkitiivisteet ovat uusimpien kansainvälisten teknisten standardien mukaisia ja ne kattavat ATEX, IECEx, cCSAus ja UL -hyväksynnät.

show blocks helper

Näytetään tulokset 1–9 / 48

  • A Series

    A Series (10)

  • C Series

    C Series (4)

  • E Series

    E Series (6)

  • PX REX Series

    PX REX Series (7)

  • PX Series

    PX Series (6)

  • SS Series

    SS Series (4)

  • TMC/2 Series

    TMC/2 Series (3)

  • TMCX/2

    TMCX/2 (2)

  • Triton Series

    Triton Series (5)

  • TSMe- / TSPe- Atex holkkitiivisteet

    TSMe- / TSPe- Atex holkkitiivisteet (2)

  • CMP – Triton CDS (T3CDS) holkkitiiviste

    Ex eb, Ex db, Ex nR, Ex ta
    Explosive Atmosphere Cable Gland

    For all types of Armoured Cables

    • Fully sequential, three step installation procedure
    • Reduces installation times, cost & risk
    • Direct & remote installation
    • Unique compensating displacement seal system (CDS)
    – Metal-to-metal installation every time regardless of cable diameter
    • Designed to prevent Coldflow, see CMP Technical Document TS002 (available upon request)
    • Integral protected deluge seal
    • Controlled outer ‘load retention’ seal
    • Unique OSTG prevents overtightening
    • -60°C to +130°C (standard), -20°C to 200°C (ThermEx option T3CDSHT)
    • Globally marked, IECEx, ATEX, UL & cCSAus
    • EMC tested

  • CMP – Triton CDS PB (T3CDSPB) holkkitiiviste

    Ex eb, Ex db, Ex nR, Ex ta
    Explosive Atmosphere Cable Gland for all types of Lead Sheathed Armoured Cables

    • Effectively earths / grounds lead sheathed cables
    • Fully sequential, three step installation procedure
    • Direct & remote installation
    • Unique compensating displacement seal system (CDS)
    – Metal-to-metal installation every time regardless of lead sheath diameter
    • Designed to prevent Coldflow, see CMP Technical Document TS002 (available upon request)
    • Integral protected deluge seal
    • Controlled outer ‘load retention’ seal
    • Unique OSTG prevents overtightening
    • -60°C to +130°C
    • Globally marked, IECEx, ATEX, UL & cCSAus
    • EMC tested

  • CMP – Triton TE1FU holkkitiiviste

    Ex eb, Ex db, Ex nR, Ex ta
    Explosive Atmosphere Cable Gland for all types of Armoured Cables

    • Stainless steel compact design
    • Fully sequential, three step installation procedure
    • Reduces installation times, cost & risk
    • Direct & remote installation
    • Unique compensating displacement seal system(CDS)
    • Metal-to-metal installation regardless of cable bedding diameter
    • Designed to prevent Coldflow, see CMP Technical Document TS002 (available upon request)
    • Integral protected deluge seal
    • Controlled outer ‘load retention’ seal
    • Unique OSTG prevents overtightening
    • -60°C to +130°C
    • Globally marked, IECEx, ATEX & cCSAus
    • EMC tested

  • CMP – Triton TE1FUPB holkkitiiviste

    Ex eb, Ex db, Ex nR, Ex ta
    Explosive Atmosphere Cable Gland for all types of Lead Sheathed Armoured Cables

    • Stainless steel compact design
    • Effectively earths / grounds lead sheathed cables
    • Fully sequential, three step installation procedure
    • Reduces installation times, cost & risk
    • Direct & remote installation
    • Unique compensating displacement seal system(CDS)
    • Metal-to-metal installation regardless of lead sheath diameter
    • Designed to prevent Coldflow, see CMP Technical Document TS002 (available upon request)
    • Integral protected deluge seal
    • Controlled outer ‘load retention’ seal
    • Unique OSTG prevents overtightening
    • -60°C to +130°C
    • Globally marked, IECEx, ATEX & cCSAus
    • EMC tested

  • CMP – A2F100 holkkitiiviste

    Ex eb, Ex db, Ex nR, Ex ta
    Explosive Atmosphere Cable Gland

    For all types of Unarmoured & Braided Cables

    • Complies 100% with IEC 60079-0 cable retention requirements
    • No external cable clamping required
    • No special conditions for safe use
    • Displacement type flameproof seal
    • Deluge protected
    • -60°C to +130°C
    • Internationlly marked, IECEx, ATEX

  • CMP – RA2e100 holkkitiiviste

    Ex eb, Ex nR, Ex ta
    Explosive Atmosphere Cable Gland

    For all types of Unarmoured & Braided Cables

    • Supplied with face seal
    • Complies 100% with IEC 60079-0 cable retention requirements
    • No external cable clamping required
    • No special conditions for safe use
    • Displacement type seal
    • Deluge protected
    • -60°C to +130°C
    • Internationally marked, IECEx & ATEX
    • 10mm thread lengths available upon request (sizes 32 and below)

  • CMP – A2e100 holkkitiiviste

    Ex eb, Ex nR, Ex ta
    Explosive Atmosphere Cable Gland

    For all types of Unarmoured & Braided Cables

    • Complies 100% with IEC 60079-0 cable retention requirements
    • No external cable clamping required
    • No special conditions for safe use
    • Displacement type seal
    • Deluge protected
    • -60°C to +130°C
    • Internationally marked, IECEx & ATEX
    • 10mm thread lengths available upon request (sizes 32 and below)

  • CMP – A2F holkkitiiviste

    Ex eb, Ex db, Ex nR, Ex ta
    Explosive Atmosphere Cable Gland

    For all types of Unarmoured & Braid Armour Cables

    • Displacement type flameproof seal
    • Deluge protected
    • -60°C to +130°C (standard), -60°C to 180°C (ThermEx option A2FHT)
    • Globally marked, IECEx, ATEX & CSA
    • Class I Zone 1, Class I Division 2 BCD (Canada Only)

  • CMP – A2e holkkitiiviste

    Ex eb, Ex nR, Ex ta
    Explosive Atmosphere Cable Gland

    For all types of Unarmoured & Braid Armour Cables

    • 10mm thread length on sizes 32 and below
    • Displacement type flameproof seal
    • Deluge protected
    • -60°C to +130°C
    • Internationally marked, IECEx & ATEXX